Ferrotec’s Thermoelectric Module Model Numbers
| 95 | 0 | 0 | / | 127 | / | 060 | B | X |
| Product Line | Shape | Classification Number | / | Number of Couples | / | Maximum Current | Substrate specification | Options |
Product Line
95-series
High Reliability, Lead-Free, 200°C Maximum process temperature—During normal operation we generally recommend an upper limit of 135°C for sustained operation
70-series
Long life, lead-free, 200°C Max
Shape
0
Standard single-stage module
1
undesignated
2
2 stage module
3
3 stage module
Classification Number
Number for Ferrotec internal use
Number of Couples
May provide additional performance information
Maximum Current
0.1 Ampere Increments
Substrate specification
A
Standard type, plain ceramic surface applied for miniature modules only—height toleratnce = +/- 0.15 mm
B
Lapped type, plain ceramic surface.
Single stage modules—height tolerance = +/- 0.025 mm
Multi stage modules—height tolerance = +/- 0.10 mm
H
Solderable, metalized ceramic on hot side external surface
C
Solderable, metalized ceramic on cold side external surface
M
Solderable, metalized ceramic on both hot and cold side external surfaces
Options
S
RTV Silicon Seal
X